NIRS™ DS3

The NIRS™ DS3 analyser is always ready, delivers results you can trust and offers many smart data sharing and calibration management options. Get the information you need to make the necessary decisions and get full control of your sample preparation. Shorten your turnaround time, reduce waste and reduce the use of harmful chemicals to optimise cost and ensure sustainable operations, while sample matching allows you to improve quality control.

See how it works
NIRS DS3 Product Picture
Sample Icon

Analyse

A wide range of food and feed matrices such as bread, pasta, ready to go meals, sausage and more.
Parameter Icon

Parameters

Fat, protein, moisture, ash, starch plus the option to develop specialised calibrations such as amino acids, NDF, ADF, dietary fibre, sugar and more for selected matrixes.
Value Icon

Value

Improve laboratory processes by knowing the expected value of samples. Save cost of consumables by choosing the correct method e.g. de-fating/ de- sugaring etc. Reduce the need for reanalysis and improve turnaround time.

 

 

New opportunities with fast indirect screening

 

Consumer demands for product innovation and government regulations on healthy products are driving a diversification of product types throughout the food industry. For busy testing laboratories already faced with staffing challenges, increased competition and demands for fast turnaround time, the surge of new sample types with unknown constituents is adding significant pressure on laboratory operations.

 

In this context, integrating a fast, indirect method such as NIR proves valuable as a tool to improving your daily operations. Fast screening of samples with NIRS™ DS3 offers new opportunities to increase efficiency, optimize capacity and minimize time-consuming and costly re-runs.

 

Versatile performance for a wide range of sample types

NIRS™ DS3 is an advanced and versatile solution for direct measurement of a wide range of food and feed matrices from animal feed to bread, pasta, ready-made meals and more - the list of many diverse applications for the superbly versatile NIRS™ DS3 continues. 

 

Unground, ground and liquid samples can be measured with new levels of analytical performance with no or very limited sample preparation.

 

DS3 feature spot samples

Wondering how to improve your lab flow with NIR laboratory equipment?

Get an obligation free analysis about profit and quality improvement opportunities for your specific laboratory procedures.

Get a quote Let's talk

Features

  • Automated sample transfer

    Automated sample transfer reduces time spent on transferring data to and from management systems 
     

  • Scheduled diagnostics

    Running instrument diagnostics is essential to maintain high analytical performance of your NIR laboratory equipment, but it is also time consuming and limits access to the instrument.


    With scheduled diagnostics, you can ensure that your instrument is always ready during working hours, with full confidence in your results.

     
  • FossManager™

    FossManager™ software allows instruments to be connected in a network making it easier, quicker and more reliable to manage individual or multiple instruments from a desktop located anywhere. 
  • Ready-to-use calibrations or tools to develop your own

    FOSS global ANN calibrations are built on thousands of samples from a large variety of raw materials. Alternatively, develop your own calibrations with the easy to use FossCalibrator™ tool.

Streamline your sample preparation with NIR

In this video, Concept Developer, Olivia Greulich explains how the NIRS™ DS3 can take the pressure of your laboratory operations in the sample preparation phase. Learn how to streamline your sample preparation, save time, reduce the use of chemicals and deliver fast results.
ALS

Take the guesswork out of sample analysis with rapid screening methods

As the food industry drives towards ever increasing product innovation, laboratories are faced with a higher throughput of more varied and unknown sample types. We spoke to Global Technical Manager for food chemistry, Timothy Lumb from ALS about the challenges facing the testing industry today and the possible solutions. Read article

Improve turnaround time with fast and reliable test data

The innovative NIRS DS3 makes it easier to exploit fast and accurate analysis of samples, making it ideal for sample preparation, quality control and adding more revenue

 

  • Know the expected values of incoming samples to avoid re-runs, reduce the use of chemicals and improve your analytical workflow.

  • Achieve new levels of confidence in analytical data through consistent high performance. 

  • Ensure that critical analysis data for decision-making is always available with high uptime.
Banner with text

Webinar: Grow your business and become more sustainable with NIR soil solutions

In laboratories today, we see an increasing focus on becoming more sustainable and reducing the use of harmful chemicals without compromising on quality and accuracy. Learn why NIR is rapidly gaining acceptance as a reliable method for soil analysis, that is fast, accurate and sustainable, and get insights into the practical use of NIR for soil testing. This recorded webinar is hosted by soil application expert, Nicolai Bork and guest speaker, Dr. Andreas Zumdick, global business manager, at laboratory service providers, SGS.

Webinar: Grow your business and become more sustainable with NIR soil solutions

In laboratories today, we see an increasing focus on becoming more sustainable and reducing the use of harmful chemicals without compromising on quality and accuracy. Learn why NIR is rapidly gaining acceptance as a reliable method for soil analysis, that is fast, accurate and sustainable, and get insights into the practical use of NIR for soil testing. This recorded webinar is hosted by soil application expert, Nicolai Bork and guest speaker, Dr. Andreas Zumdick, global business manager, at laboratory service providers, SGS.

Soil
Please provide your first name
Please provide your last name
Please provide a valid email address
Please provide company name
Please provide your job title
Please provide country code
Please provide state code

Something went wrong!

Sorry, we were not able to send your form.

Technical specification

Products measured and product presentation
Feature                                                          Specification
Dimensions (WxDxH) 375 x 490 x 300 mm
Weight 27 kg
Degree of protection  IP 65
Measurement mode Reflectance or transflectance (for liquids) 
Wavelength range 400 – 2500 nm
Detector Silicon (400 – 1100 nm), Lead Sulphide, PbS (1100 – 2500 nm)
Optical bandwidth 8.75 +- 0.1 nm
Data resolution 0.5 nm
Number of data points 4200
Number of subsamples Default: 7 for small cup; 8 for large cup
Self test 12 minutes (variable)
Analysis time <1 minute for 32 scans (8 subsamples, 4 scans per subsample)
Network connections FossManagerTM
Installation requirements
Voltage supply 100-240 V AC*, frequency 50-60 Hz, Class 1, protective earth

Ambient temperature

5 - 40oC
Storage temperature -20 to 70oC
Ambient humidity <93% RH
Mechanical enviroment Stationary during use
EMS enviroment  Laboratory use, industry requirements
 *Mains supply voltage fluctuations not exceeding ±10% of the rated voltage.
   
Optional services
Digital Services FossAssure™
Digital Solutions FossCare™, SmartCare™

Brochures and Papers

Stay informed - with insights and news from FOSS

Stay ahead of your competitors! Get fresh knowledge and valuable insights about trends, challenges and opportunities related to analytics in your business, directly in your inbox.

Something went wrong!

Sorry, we were not able to send your form.
back to top icon
The content is hosted on YouTube.com (Third Party). By showing the content you accept the use of Marketing Cookies on Fossanalytics.com. You can change the settings anytime. To learn more, visit our Cookie Policy.